High-fidelity, portable, wirelessly-controlled, high-fidelity simulator showing dynamic airways and lung compliance, fully responsive during transportation
Technical features:
Displaceable technology, which allows the communication systems, compressor and power supply to be incorporated into the simulator, eliminating external tubing, cables and compressors.
Allows the use of real devices: connect the simulator directly to a real ventilation system. A real monitor for 12-lead ECG recording, pulse oximeter, blood pressure cuff, external defibrillator and real external pacemaker can be used.
General:
- Power supply from an internal rechargeable battery or fixed plug;
- Wireless tablet-controllable simulator - coverage up to 300 meters;
- Pre-programmed scenarios can be used, or you can create your own quickly and easily;
Respiratory tree:
- Programmable respiratory tree: lingual and pharyngeal edema, laryngospasm;
- Numerous upper airway sounds synchronized with breathing;
- Allows endotracheal intubation and retrograde intubation;
- Intubation on the right main bronchus;
- Intubation depth detection sensors;
- Perform the Sellick maneuver to highlight the vocal cords;
- Realistic trachea - allows tracheostomy and needle cricothyroidotomy.
Breathing:
- Control of breathing rate and depth of breathing;
- Separate lung sounds for each lung, at the level of the hemithorax, both upper and lower, anterior and posterior;
- Thoracic chest sounds and breath sounds synchronized with breathing patterns;
- CO2 exhalation during exhalation (4 levels) - refillable cartridge, mounted inside the simulator;
- Assisted ventilation with real mechanical fans;
- Bilateral chest enlargement;
- Unilateral chest enlargement - simulated pneumothorax;
- Needle decompression, intercostal space II, bilateral;
- Dynamic respiratory tree and lung compliance/resistance;
- 10 levels of static compliance; 15 - 50 ml/cm H2O
- 10 levels of respiratory tree strength;
- Supports PEEP between 5 - 20 cm H2O
- Possibility to assist the ventilator at different breathing rates;
- The compliance and strength of the breathing tree may change during the use of the artificial ventilation system.
Cord:
- Real-time ECG generation with physiological variations;
- Auscultation of heart sounds, synchronized with ECG recording;
- View 12-lead ECG in dynamic;
- 12-lead ECG with integrated acute myocardial infarction (AMI) module.
Circulation:
- Blood pressure measurable by palpatory or auscultatory method with real equipment
- Korotkoff noise;
- Oxygen saturation measurable with real oximeters;
- Pulse palpation regions;
- Pulse synchronized with heart rate and BP;
- Vascular network in both arms for intravenous access;
- Regions for intramuscular and subcutaneous injections;
- Intraosseous access to the tibia;
- ECG monitoring with real devices;
- Defibrillation, cardioversion and pacing with real devices;
- Numerous noises and heart rates;
- ECG rhythm generated in real time;
- Heart sounds synchronized with ECG;
- Bilateral carotid, brachial, radial, femoral, popliteal and pedal pulses, synchronized with ECG;
- Pulse varies with BP, is continuous and synchronized with ECG even during pacing
Controlled by instructor or on Automatic mode:
- Vital parameters are generated in real time;
- Drug library;
- The use of medication influences the patient's condition in real time, simulating real clinical situations.
Medication recognition system:
- Identifies the drug and volume delivered to the venous network of the right hand and forearm;
- Delivered with 100 syringes with wireless tags;
- The medication contained in the library can be used, or other medications can be added using templates in the system.
Neurological response:
- The eyes can be controlled automatically (via the physiological model) or directly, manually (by the instructor);
- You can select the pupillary response to light stimulation.
Language:
- Streaming audio wireless;
- One can create and record voice replies in any language.
Vital functions monitor:
- Wireless tablet control;
- Use default configuration, or customization, to simulate a real monitor;
- Image distribution: ultrasounds, CT scans, lab results;
- Touchscreen control;
- The monitor can be configured by the instructor to fit the scenario.
Joints and mobility:
- Seizures.
Other:
- Central cyanosis;
- Urinary reservoir; Foley catheterization;
- Interchangeable genitalia;
- Nasogastric probe;
- Auscultation bowel sounds.
User interface:
- Sensors to track student activity;
- Condition changes and interventions are time-framed and recorded;
- Wireless tablet plus vital signs monitor
- 26 pre-programmed scenarios, which can be modified by the instructor even while they are running;
- Create your own scenarios using the Add / Edit functions;
- Change the simulator state even while the scenario is running.
Accessories:
- S3201.004 Leg amputation
- S3201.005 Arm amputation
- WK120 Accident kit
- WK100 Emergency kit
- WK110 Trauma kit
- WK105 Burns kit